Products / Neutron Diagnostics / Diamond Fast-Neutron Monitor
Product enquiries: office@cividec.at
A3 DIAMOND FAST-NEUTRON MONITOR
The Fast-Neutron Counter
The Diamond Fast-Neutron Monitor is designed for neutron flux monitoring in fusion reactor applications. High neutron flux rates are measured with the C2-HV Broadband Amplifier, while high-precision neutron spectroscopy is performed with the Cx-L Spectroscopic Amplifier. Both included amplifiers allow the installation of a 10 m long detector cable between detector and amplifier, for operation in high-radiation environments.
Ideal for measurements of neutrons in fusion reactors.
FEATURES
Detector type:
B7 Fast-Neutron Diamond Detector
Active volume:
4 mm x 4 mm x 0.5 mm
Neutron energies:
> 1 MeV
Counting rate:
50 MHz with C2-HV Broadband Amplifier
Energy resolution:
20 keV FWHM with Cx-L Spectroscopic Amplifier
OPTIONS
The A3 Diamond Fast-Neutron Monitor can be provided with alternative detector designs and as self-standing monitoring system:
  • Slim detectors with Ø12 mm for the insertion into confined spaces.
  • Temperature resistant detector up to 500 K.
  • Vacuum compatible detector up to UHV.
  • Full Diamond Fast-Neutron Monitoring System including ROSY® AX106 with integrated Neutron Spectroscopy Application for real-time neutron beam monitoring.
  • Full Diamond Fast-Neutron Monitoring System including ROSY® AX106 with Neutron Spectroscopy Application and integrated HV and LV power supply, as autonomous, turn-key neutron monitoring system.
ADDITIONAL PRODUCT INFORMATION
The A3 Diamond Fast-Neutron Monitor is especially suited for d-t fusion reactor applications, where the 12C(n,α)9Be reaction is used to measure the neutron flux.

The spectrum of 14 MeV neutrons recorded with the Fast-Neutron Monitor, using the Cx-L Spectroscopic Amplifier is shown in the Figure. The characteristic structures of the detector response function can clearly be distinguished from each other. The separated peak of 12C(n,α)9Be is used for neutron flux monitoring in 14 MeV neutron beams.
In d-d fusion plasma reactors the response function of the Diamond Fast-Neutron Detector is dominated by the elastic scattering of neutrons on the Carbon nuclei of the diamond sensor. The maximum deposited energy in the diamond sensor is well below 1 MeV.

With the A3 Diamond Fast-Neutron Monitor and the ROSY® Neutron Spectroscopy Application the presented spectrum in blue was recorded with d-d fusion neutrons. The measurement is well in agreement with the Geant4 simulated spectrum. For the monitoring of the d-d neutron flux the high energy part of the spectrum is used, with a trigger level at 400 keV energy deposition in the diamond sensor.
DOWNLOAD THE PRODUCT INFORMATION
A3 Diamond Fast-Neutron Monitor

This product information download contains the following CIVIDEC documents :
RELEVANT PUBLICATIONS
Selective data analysis for diamond detectors in neutron fields
C. Weiss, et al., EPJ Web of Conferences, 146, 03004, 2017

DOI:10.1051/epjconf/201714603004

The 13C(n,α0)10Be cross section at 14.3 MeV and 17 MeV neutron energy
P. Kavrigin, et al., EPJ Web of Conferences, 146, 11036, 2017

DOI:10.1051/epjconf/201714611036

Ionization Signals from Diamond Detectors in Fast-Neutron Fields
C. Weiss, et al., Eur. Phys. J. A., 52, 269, 2016

DOI:10.1140/epja/i2016-16269-8

13C(n,α0)10Be Cross Section Measurement with sCVD Diamond Detector
P. Kavrigin, et al., Eur. Phys. J. A, 52, 179, 2016

DOI:10.1140/epja/i2016-16179-9

A CVD Diamond Detector for (n,α) Cross-Section Measurements
C. Weiss, PhD Thesis, Technische Universität Wien, Faculty of Physics, 2014


A new CVD Diamond Mosaic-Detector for (n,α) Cross-Section Measurements at the n_TOF Experiment at CERN
C. Weiss, et al., NIMA, 732, 190-194, 2013

DOI:10.1016/j.nima.2013.07.040

Response of CVD Diamond Detectors to 14 MeV Neutrons
C. Weiss, et al., CERN-ATS-Note-2012-093 TECH, 2012